Withnell Sensors - Spell Out Logo
LogTag UTRID-16 USB Temperature Data Logger – image 1
LogTag UTRID-16 USB Temperature Data Logger – image 2
LogTag UTRID-16 USB Temperature Data Logger – image 3
LogTag UTRID-16 USB Temperature Data Logger – image 4
LogTag UTRID-16 USB Temperature Data Logger – image 5
LogTag UTRID-16 USB Temperature Data Logger – image 1
LogTag UTRID-16 USB Temperature Data Logger – image 2
LogTag UTRID-16 USB Temperature Data Logger – image 3
LogTag UTRID-16 USB Temperature Data Logger – image 4
LogTag UTRID-16 USB Temperature Data Logger – image 5

LogTag UTRID-16 USB Temperature Data Logger

The LogTag UTRID-16 is a reusable temperature data logger with an internal sensor, integrated display and built-in USB connector.

It records temperatures from -30°C to +60°C and stores more than 16,000 readings. Current conditions and alarm statistics can be reviewed on the display, while a detailed PDF report is generated automatically when the logger is connected to a computer.

  • Internal temperature monitoring from -30°C to +60°C
  • Built-in USB with automatic PDF reporting
  • Stores 16,129 time-stamped temperature readings

Automatic PDF Reports

Connect the logger directly to a computer to generate a permanent PDF report without specialist software.

Immediate Status Checks

Review the current temperature, recording status, alarm conditions and excursion durations on the integrated display.

Six Configurable Alarms

Configure three upper and three lower alarms to monitor different temperature limits and excursion conditions.

Extended Recording Capacity

Store up to 168 days of data at 15-minute intervals without frequent downloads.

The UTRID-16 is suited to applications requiring portable temperature monitoring, on-screen status information and simple downloadable reports.

Typical applications include:

  • Pharmaceutical storage and distribution
  • Vaccine transportation
  • Medical and healthcare products
  • Laboratory refrigerators
  • Cold rooms and refrigerated storage
  • Food and produce transportation
  • Warehouses and distribution centres
  • Temperature-controlled containers
  • Clinical and research laboratories
  • General cold chain monitoring

The internal sensor measures the environment immediately surrounding the logger, allowing the device to be positioned directly alongside the monitored products.

The UTRID-16 combines high-capacity temperature recording with an integrated display, flexible alarms and direct USB reporting.

  • Internal temperature measurement from -30°C to +60°C
  • Memory for 16,129 temperature readings
  • Up to 112 days of data at 10-minute intervals
  • Up to 168 days of data at 15-minute intervals
  • Integrated LCD showing the current temperature
  • On-screen recording and alarm status
  • Display of temperature excursion durations
  • Three configurable upper alarms
  • Three configurable lower alarms
  • Configurable sampling intervals from 30 seconds to 18 hours
  • Push-button or scheduled recording start
  • Optional start delay of up to 72 hours
  • Built-in USB 2.0 connection
  • Automatic generation of PDF reports
  • Compatible with LogTag Analyzer
  • Built-in real-time clock
  • IP64-rated with the USB cap fitted
  • Fixed battery providing approximately two years of normal use
  • WHO PQS-qualified under code E006/076

No separate LogTag interface cradle is required to configure the logger or download reports.

SpecificationUTRID-16
Temperature measurement range-30°C to +60°C
Operating temperature range-30°C to +65°C
Storage temperature range0°C to +40°C
Temperature accuracyBetter than ±0.5°C from -20°C to +40°C; better than ±0.7°C elsewhere
Temperature resolution0.1°C
Sensor response timeTypically less than seven minutes in moving air
Recording capacity16,129 temperature readings
Sampling intervalConfigurable from 30 seconds to 18 hours
Start optionsPush-button or scheduled start, with an optional delay of up to 72 hours
AlarmsThree configurable upper and three configurable lower alarms
Reporting and connectionUSB 2.0 with automatic PDF report generation
Environmental protectionIP64 with the USB cap fitted
BatteryFixed CR2450 3V LiMnO2 battery
Size and weight93 x 54.5 x 8.6mm including USB cap; 39g

The fixed battery provides approximately two years of normal operation, based on six-minute logging, monthly downloads and limited daily display use.

Why Choose the LogTag UTRID-16?

The LogTag UTRID-16 provides a practical way to monitor temperature while giving users immediate access to current conditions, recording status and alarm information.

Its internal sensor and compact design allow the logger to travel directly alongside temperature-sensitive products. Six configurable alarms and a large memory capacity support a wide variety of storage and transportation requirements.

The integrated USB connector removes the need for a separate interface cradle and automatically generates a PDF report. The complete dataset can also be opened in LogTag Analyzer for further analysis, graphing and export.

DOWNLOAD

LogTag UTRID-16 Technical Brochure

Download the manufacturer’s brochure for complete specifications, display functions, alarm settings and reporting information.

team-headshot team-headshot team-headshot
30+

Similar products