Withnell Sensors - Spell Out Logo
Kambic Humidity Chambers – image 1
Kambic Humidity Chambers – image 2
Kambic Humidity Chambers – image 3
Kambic Humidity Chambers – image 4
Kambic Humidity Chambers – image 5
Kambic Humidity Chambers – image 6
Kambic Humidity Chambers – image 7
Kambic Humidity Chambers – image 8
Kambic Humidity Chambers – image 9
Kambic Humidity Chambers – image 10
Kambic Humidity Chambers – image 11
Kambic Humidity Chambers – image 12
Kambic Humidity Chambers – image 13
Kambic Humidity Chambers – image 14
Kambic Humidity Chambers – image 15
Kambic Humidity Chambers – image 16
Kambic Humidity Chambers – image 17
Kambic Humidity Chambers – image 18
Kambic Humidity Chambers – image 19
Kambic Humidity Chambers – image 20
Kambic Humidity Chambers – image 21
Kambic Humidity Chambers – image 22
Kambic Humidity Chambers – image 23
Kambic Humidity Chambers – image 24
Kambic Humidity Chambers – image 25
Kambic Humidity Chambers – image 26
Kambic Humidity Chambers – image 27
Kambic Humidity Chambers – image 28
Kambic Humidity Chambers – image 29
Kambic Humidity Chambers – image 1
Kambic Humidity Chambers – image 2
Kambic Humidity Chambers – image 3
Kambic Humidity Chambers – image 4
Kambic Humidity Chambers – image 5
Kambic Humidity Chambers – image 6
Kambic Humidity Chambers – image 7
Kambic Humidity Chambers – image 8
Kambic Humidity Chambers – image 9
Kambic Humidity Chambers – image 10
Kambic Humidity Chambers – image 11
Kambic Humidity Chambers – image 12
Kambic Humidity Chambers – image 13
Kambic Humidity Chambers – image 14
Kambic Humidity Chambers – image 15
Kambic Humidity Chambers – image 16
Kambic Humidity Chambers – image 17
Kambic Humidity Chambers – image 18
Kambic Humidity Chambers – image 19
Kambic Humidity Chambers – image 20
Kambic Humidity Chambers – image 21
Kambic Humidity Chambers – image 22
Kambic Humidity Chambers – image 23
Kambic Humidity Chambers – image 24
Kambic Humidity Chambers – image 25
Kambic Humidity Chambers – image 26
Kambic Humidity Chambers – image 27
Kambic Humidity Chambers – image 28
Kambic Humidity Chambers – image 29

Kambic Humidity Chambers

[22 Models]

Kambic Humidity Chambers deliver precise control of temperature and relative humidity for laboratories and manufacturers carrying out environmental testing, stability studies and product qualification.

Designed to simulate real-world conditions with exceptional accuracy, the range provides reliable and repeatable performance for industries where environmental conditions directly influence product quality, safety and compliance.

Available in Standard Temperature (+5°C to +180°C), Low Temperature (-40°C to +180°C) and Ultra Low Temperature (-75°C to +180°C) configurations, Kambic Humidity Chambers are available in chamber volumes from 50L to 1000L, allowing you to select the ideal solution for your testing requirements.

  • Temperature ranges from +5°C to +180°C or -75°C to +180°C
  • Relative humidity control from 10% to 98% RH
  • Standard, Low Temperature and Ultra Low Temperature models available

Wide Temperature Range

Choose from standard, low temperature and ultra-low temperature humidity chambers operating between +5°C and +180°C or -75°C and +180°C.

Precise Humidity Control

Maintain accurate environmental conditions with relative humidity control from 10% to 98% RH for repeatable testing.

Exceptional Stability

Industry-leading temperature and humidity stability deliver consistent, repeatable results for demanding laboratory and industrial applications.

Intelligent Process Control

Programmable PLC controls support ramping, cycling, timed programmes and remote communications for automated environmental testing.

Kambic Humidity Chambers are used across laboratories, research facilities and manufacturing environments for a wide range of environmental testing applications, including:

  • Sample conditioning before testing
  • Stability testing
  • Environmental simulation
  • Accelerated ageing
  • Product qualification testing
  • Material testing
  • Pharmaceutical stability studies
  • Electronics testing
  • Automotive component testing
  • Aerospace qualification
  • Packaging testing
  • Sensor and data logger calibration

Kambic Humidity Chambers are used across laboratories, research facilities and manufacturing environments for a wide range of environmental testing applications, including:

  • Stability testing
  • Environmental simulation
  • Accelerated ageing
  • Product qualification testing
  • Material testing
  • Pharmaceutical stability studies
  • Electronics testing
  • Automotive component testing
  • Aerospace qualification
  • Packaging testing
  • Sensor and data logger calibration
  • Sample conditioning before testing

Standard Temperature Chambers

SpecificationKK-50 CHKK-105 CHKK-190 CHKK-340 CHKK-500 CHKK-1000 CH
Volume50 L105 L190 L340 L500 L1,000 L
Temperature range+5°C to +180°C+5°C to +180°C+5°C to +180°C+5°C to +180°C+5°C to +180°C+5°C to +180°C
Relative humidity range10% to 98% RH10% to 98% RH10% to 98% RH10% to 98% RH10% to 98% RH10% to 98% RH
External dimensions (W×H×D)570 × 1,035 × 645 mm725 × 1,560 × 845 mm834 × 1,675 × 930 mm835 × 1,895 × 1,115 mm1,035 × 1,810 × 1,270 mm1,235 × 1,930 × 1,495 mm
Internal dimensions (W×H×D)400 × 375 × 350 mm490 × 498 × 430 mm600 × 610 × 510 mm600 × 830 × 685 mm800 × 800 × 800 mm1,000 × 1,000 × 1,000 mm
Maximum load30 kg60 kg80 kg100 kg150 kg200 kg
Temperature stability±0.05°C at 50°C/50% RH
±0.05°C at 90°C/90% RH
±0.2°C at 180°C
±0.05°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.3°C at 180°C
±0.06°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.3°C at 180°C
±0.06°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.2°C at 180°C
±0.06°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.2°C at 180°C
±0.05°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.3°C at 180°C
Temperature uniformity±0.4°C at 50°C/50% RH
±0.4°C at 90°C/90% RH
±1.6°C at 180°C
±0.3°C at 50°C/50% RH
±0.4°C at 90°C/90% RH
±1.8°C at 180°C
±0.4°C at 50°C/50% RH
±0.4°C at 90°C/90% RH
±2.0°C at 180°C
±0.3°C at 50°C/50% RH
±0.4°C at 90°C/90% RH
±1.5°C at 180°C
±0.3°C at 50°C/50% RH
±0.4°C at 90°C/90% RH
±1.6°C at 180°C
±0.4°C at 50°C/50% RH
±0.4°C at 90°C/90% RH
±1.8°C at 180°C
Wattage2,300 W3,200 W3,600 W3,600 W9,000 W12,000 W
Relative humidity stability±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.6% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH

Low Temperature Chambers

SpecificationKK-50 CHLTKK-105 CHLTKK-190 CHLTKK-340 CHLTKK-500 CHLTKK-1000 CHLT
Volume50 L105 L190 L340 L500 L1,000 L
Temperature range−40°C to +180°C−40°C to +180°C−40°C to +180°C−40°C to +180°C−40°C to +180°C−40°C to +180°C
Relative humidity range10% to 98% RH10% to 98% RH10% to 98% RH10% to 98% RH10% to 98% RH10% to 98% RH
External dimensions (W×H×D)570 × 1,035 × 645 mm725 × 1,560 × 845 mm834 × 1,675 × 930 mm835 × 1,895 × 1,115 mm1,035 × 1,810 × 1,270 mm1,235 × 1,930 × 1,495 mm
Internal dimensions (W×H×D)400 × 375 × 350 mm490 × 498 × 430 mm600 × 610 × 510 mm600 × 830 × 685 mm800 × 800 × 800 mm1,000 × 1,000 × 1,000 mm
Maximum load30 kg60 kg80 kg100 kg150 kg200 kg
Temperature stability±0.2°C at −40°C
±0.05°C at 50°C/50% RH
±0.05°C at 90°C/90% RH
±0.2°C at 180°C
±0.4°C at −40°C
±0.08°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.3°C at 180°C
±0.5°C at −40°C
±0.08°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.2°C at 180°C
±0.5°C at −40°C
±0.08°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.2°C at 180°C
±0.5°C at −40°C
±0.06°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.2°C at 180°C
±0.5°C at −40°C
±0.05°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.2°C at 180°C
Temperature uniformity±1.0°C at −40°C
±0.4°C at 50°C/50% RH
±0.4°C at 90°C/90% RH
±1.5°C at 180°C
±1.0°C at −40°C
±0.3°C at 50°C/50% RH
±0.3°C at 90°C/90% RH
±2.0°C at 180°C
±1.0°C at −40°C
±0.5°C at 50°C/50% RH
±0.5°C at 90°C/90% RH
±1.8°C at 180°C
±1.0°C at −40°C
±0.3°C at 50°C/50% RH
±0.4°C at 90°C/90% RH
±1.5°C at 180°C
±0.7°C at −40°C
±0.3°C at 50°C/50% RH
±0.4°C at 90°C/90% RH
±1.5°C at 180°C
±0.7°C at −40°C
±0.5°C at 50°C/50% RH
±0.5°C at 90°C/90% RH
±1.5°C at 180°C
Wattage2,300 W3,200 W3,600 W3,600 W9,000 W12,000 W
Relative humidity stability±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.6% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH

Ultra-Low Temperature Chambers

SpecificationKK-105 CHULTKK-190 CHULTKK-340 CHULTKK-500 CHULTKK-1000 CHULT
Volume105 L190 L340 L500 L1,000 L
Temperature range−75°C to +180°C−75°C to +180°C−75°C to +180°C−75°C to +180°C−75°C to +180°C
Relative humidity range10% to 98% RH10% to 98% RH10% to 98% RH10% to 98% RH10% to 98% RH
External dimensions (W×H×D)850 × 1,715 × 1,100 mm940 × 1,830 × 1,125 mm940 × 2,052 × 1,310 mm1,165 × 1,985 × 1,640 mm1,375 × 2,070 × 1,900 mm
Internal dimensions (W×H×D)530 × 500 × 460 mm620 × 590 × 515 mm620 × 810 × 690 mm870 × 800 × 800 mm1,070 × 1,000 × 1,000 mm
Maximum load60 kg80 kg100 kg150 kg200 kg
Temperature stability±1.0°C at −75°C
±0.08°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.2°C at 180°C
±1.0°C at −75°C
±0.08°C at 50°C/50% RH
±0.08°C at 90°C/90% RH
±0.4°C at 180°C
±1.0°C at −75°C
±0.08°C at 50°C/50% RH
±0.08°C at 90°C/90% RH
±0.2°C at 180°C
±1.0°C at −75°C
±0.1°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.1°C at 180°C
±1.0°C at −75°C
±0.1°C at 50°C/50% RH
±0.1°C at 90°C/90% RH
±0.1°C at 180°C
Temperature uniformity±1.5°C at −75°C
±0.5°C at 50°C/50% RH
±0.5°C at 90°C/90% RH
±1.5°C at 180°C
±1.2°C at −75°C
±0.5°C at 50°C/50% RH
±0.5°C at 90°C/90% RH
±1.7°C at 180°C
±1.2°C at −75°C
±0.5°C at 50°C/50% RH
±0.5°C at 90°C/90% RH
±1.7°C at 180°C
±1.0°C at −75°C
±0.5°C at 50°C/50% RH
±0.5°C at 90°C/90% RH
±1.0°C at −75°C
±0.5°C at 50°C/50% RH
±0.5°C at 90°C/90% RH
Wattage5,500 W6,500 W7,500 W13,000 W12,000 W
Relative humidity stability±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±0.5% at 90°C/90% RH
±0.5% at 50°C/50% RH
±1.0% at 90°C/90% RH
±0.5% at 50°C/50% RH
±1.0% a

Why Choose Kambic Humidity Chambers?

Kambic Humidity Chambers are engineered for organisations that demand accurate, repeatable environmental testing.

Whether you’re carrying out pharmaceutical stability studies, accelerated ageing, material testing or environmental simulation, the range delivers exceptional temperature and humidity control across a wide operating range.

Available in standard, low temperature and ultra-low temperature configurations, Kambic chambers combine robust construction, intelligent controls and excellent metrology performance to provide dependable results in laboratories, research facilities and manufacturing environments.

Supported by Withnell Sensors, you’ll also benefit from expert technical advice, installation support and ongoing service throughout the life of your chamber.

DOWNLOAD

Explore the Kambic Humidity Chamber Brochures

Download the brochures for technical specifications, model comparisons and configuration options.

Service & Maintenance

Preventative maintenance, equipment health checks and repair support for Haier Biomedical, FARRAR and Kambic equipment supplied by Withnell Sensors.

  • Inspecting doors, handles, gaskets and seals
  • Checking backup batteries and electrical components
  • Inspecting pipework and testing for refrigerant leaks
  • Removing ice and cleaning key components
  • Completing operational and safety checks
team-headshot team-headshot team-headshot