Withnell Sensors - Spell Out Logo
Kaye ValProbe RT Wireless Data Loggers – image 1
Kaye ValProbe RT Wireless Data Loggers – image 2
Kaye ValProbe RT Wireless Data Loggers – image 3
Kaye ValProbe RT Wireless Data Loggers – image 4
Kaye ValProbe RT Wireless Data Loggers – image 5
Kaye ValProbe RT Wireless Data Loggers – image 6
Kaye ValProbe RT Wireless Data Loggers – image 7
Kaye ValProbe RT Wireless Data Loggers – image 8
Kaye ValProbe RT Wireless Data Loggers – image 9
Kaye ValProbe RT Wireless Data Loggers – image 10
Kaye ValProbe RT Wireless Data Loggers – image 11
Kaye ValProbe RT Wireless Data Loggers – image 12
Kaye ValProbe RT Wireless Data Loggers – image 13
Kaye ValProbe RT Wireless Data Loggers – image 14
Kaye ValProbe RT Wireless Data Loggers – image 15
Kaye ValProbe RT Wireless Data Loggers – image 16
Kaye ValProbe RT Wireless Data Loggers – image 17
Kaye ValProbe RT Wireless Data Loggers – image 18
Kaye ValProbe RT Wireless Data Loggers – image 19
Kaye ValProbe RT Wireless Data Loggers – image 20
Kaye ValProbe RT Wireless Data Loggers – image 21
Kaye ValProbe RT Wireless Data Loggers – image 22
Kaye ValProbe RT Wireless Data Loggers – image 23
Kaye ValProbe RT Wireless Data Loggers – image 24
Kaye ValProbe RT Wireless Data Loggers – image 25
Kaye ValProbe RT Wireless Data Loggers – image 26
Kaye ValProbe RT Wireless Data Loggers – image 27
Kaye ValProbe RT Wireless Data Loggers – image 28
Kaye ValProbe RT Wireless Data Loggers – image 29
Kaye ValProbe RT Wireless Data Loggers – image 1
Kaye ValProbe RT Wireless Data Loggers – image 2
Kaye ValProbe RT Wireless Data Loggers – image 3
Kaye ValProbe RT Wireless Data Loggers – image 4
Kaye ValProbe RT Wireless Data Loggers – image 5
Kaye ValProbe RT Wireless Data Loggers – image 6
Kaye ValProbe RT Wireless Data Loggers – image 7
Kaye ValProbe RT Wireless Data Loggers – image 8
Kaye ValProbe RT Wireless Data Loggers – image 9
Kaye ValProbe RT Wireless Data Loggers – image 10
Kaye ValProbe RT Wireless Data Loggers – image 11
Kaye ValProbe RT Wireless Data Loggers – image 12
Kaye ValProbe RT Wireless Data Loggers – image 13
Kaye ValProbe RT Wireless Data Loggers – image 14
Kaye ValProbe RT Wireless Data Loggers – image 15
Kaye ValProbe RT Wireless Data Loggers – image 16
Kaye ValProbe RT Wireless Data Loggers – image 17
Kaye ValProbe RT Wireless Data Loggers – image 18
Kaye ValProbe RT Wireless Data Loggers – image 19
Kaye ValProbe RT Wireless Data Loggers – image 20
Kaye ValProbe RT Wireless Data Loggers – image 21
Kaye ValProbe RT Wireless Data Loggers – image 22
Kaye ValProbe RT Wireless Data Loggers – image 23
Kaye ValProbe RT Wireless Data Loggers – image 24
Kaye ValProbe RT Wireless Data Loggers – image 25
Kaye ValProbe RT Wireless Data Loggers – image 26
Kaye ValProbe RT Wireless Data Loggers – image 27
Kaye ValProbe RT Wireless Data Loggers – image 28
Kaye ValProbe RT Wireless Data Loggers – image 29

Kaye ValProbe RT Wireless Data Loggers

[8 Models]

Real-time wireless measurement for process validation, combining application-specific data loggers with dedicated software for study setup, analysis and reporting.

  • View live measurements during validation studies
  • Temperature, pressure, humidity and CO₂ logger options
  • Flexible sensor configurations for chambers, equipment and process environments

Real-Time Data

View measurements as your validation study progresses.

Flexible Sensor Options

Choose rigid, flexible, bendable or surface temperature sensors.

Onboard Data Storage

Record up to 100,000 samples per sensor on applicable models.

Integrated Reporting

Bring study results, calculations and supporting records together.

Kaye ValProbe RT is a wireless process validation system designed for pharmaceutical, biotechnology, medical device and food processing applications. It combines data loggers, a base station and the Kaye Validation Console to support study setup, live measurement review, sensor verification and reporting.

Loggers transmit measurements by radio frequency to the base station, allowing users to follow conditions during a study. Internal logger memory also stores measurement data, while the base station can continue a started study independently of the console.

The range includes rigid, flexible and bendable temperature loggers, a dedicated freeze dryer surface logger, combined pressure/temperature and humidity/temperature models, and a CO₂ logger. Single, dual and five-channel temperature configurations support different measurement layouts and study requirements.

Autoclaves and Steam Sterilisation
Temperature and pressure measurements for assessing sterilisation cycles and documenting conditions across chambers and loads.

Dry Heat Sterilisers and Ovens
Bendable temperature probes support high-temperature studies, with appropriate thermal protection for the logger body and application-specific exposure limits.

Steam-in-Place and Process Vessels
Wireless measurements help assess conditions within process equipment where routing external sensor cables can be difficult.

Water Cascade Sterilisers and Washer Disinfectors
Temperature studies support assessment of heating profiles and thermal distribution during sterilisation and disinfection processes.

Incubators and Bioreactors
Temperature and CO₂ logger options support studies of controlled environments used in biological research and processing.

Stability Chambers
Combined temperature and humidity measurements help assess environmental conditions and their distribution within controlled chambers.

Freezers and Low-Temperature Storage
Suitable temperature models measure down to −85°C, supporting validation and temperature distribution studies in frozen storage environments.

Freeze Dryers and Lyophilisation
An ultra-flat surface sensor supports freeze dryer shelf temperature measurement, including applications under low vacuum.

Live Visibility During Studies
RF communication allows users to view measurements during a validation run. The console displays live results in list or graphical views, alongside calculations and event messages.

Sensor Configurations to Suit Your Equipment
Rigid, flexible, bendable and surface sensors provide options for different measurement positions. Flexible and bendable loggers are available in single, dual and five-channel configurations.

Accurate Temperature Measurements
Rigid, flexible and surface temperature models provide accuracy of ±0.1°C across −85°C to +140°C. Bendable probes extend measurement to +400°C, with model-specific ranges and accuracy specifications.

Programmable Sampling and Onboard Memory
Temperature logger sampling starts at one second, or two seconds for five-channel models, with capacity for up to 100,000 samples per sensor. The CO₂ logger uses a separate recording interval suited to gas measurements.

Dedicated Validation Console
The Kaye Validation Console provides a dedicated interface for programming loggers, reviewing live data, managing studies and generating reports.

Organised Equipment and Study Records
Setups, verification results and study files can be organised around individual assets, such as autoclaves or freezers. Supporting documents, including procedures and certificates, can be associated with the same equipment record.

Automated Sensor Verification
Compatibility with Kaye temperature references and IRTD standards supports automated verification workflows, helping users document sensor performance before and after studies.

Reporting and Data Integrity Features
Configurable calculations, report templates, electronic signatures, audit trails and user permissions support documented validation workflows and electronic record controls.

Rigid, Flexible and Surface Temperature Loggers

SpecificationRigid Temperature LoggerFlexible Temperature LoggerFreeze Dryer Surface Logger
Sensor configurationSingle sensorSingle, dual or five-channelUltra-flat surface sensor
Measurement range−85°C to +140°C−85°C to +140°C−85°C to +140°C
Temperature accuracy±0.1°C across the stated range±0.1°C across the stated range±0.1°C across the stated range
Sensor length38, 76, 152 or 229 mm1,000 mmNot applicable
Sensor diameter3 mm2.4 mm tip diameter32 mm surface diameter

Bendable Temperature Loggers

SpecificationSingle / Dual-Channel Bendable LoggerFive-Channel Bendable Logger
Sensor configurationOne or two sensorsFive sensors
Sensor measurement range−85°C to +400°C0°C to +400°C
Accuracy up to +140°C±0.1°C from −85°C to +140°C±0.1°C from 0°C to +140°C
Accuracy from +140°C to +400°C±0.25°C±0.25°C
Sensor length305, 610 or 915 mm610 mm
Sensor diameter2.4 mm2 mm

High-temperature figures apply to the sensors. The logger body requires appropriate thermal protection when exposed to conditions beyond its operating range. Insulating canister exposure limits depend on temperature and logger configuration.

Pressure/Temperature and Humidity/Temperature Loggers

SpecificationPressure/Temperature LoggerHumidity/Temperature Logger
MeasurementsAbsolute pressure and temperatureRelative humidity and temperature
Temperature measurement range0°C to +140°C0°C to +70°C
Temperature accuracy±0.1°C±0.15°C
Pressure measurement range0–5 bar absoluteNot applicable
Humidity measurement rangeNot applicable15–95% RH
Pressure accuracy±25 mbar at 0°C to +120°C; ±10 mbar at +120°C to +135°C; ±25 mbar at +135°C to +140°CNot applicable
Humidity accuracyNot applicable±2% RH across 15–95% RH, at +25°C to +40°C
Connection / sensor arrangement¼″ NPT connectionDigital RH/temperature sensor with extension cable up to 1 m
Replaceable humidity sensorNot applicableYes

CO₂ Logger

SpecificationCO₂ Logger
CO₂ measurement range0–20%
Accuracy from 0–10% CO₂±0.2% CO₂
Resolution0.01% CO₂
Measurement principleNon-dispersive infrared (NDIR)
Operating temperature0°C to +50°C
Humidity conditionsUp to 95% RH, non-condensing
Data storageUp to 100,000 samples
Recording interval2–10 minutes
Construction316 stainless steel with PEEK cover
BatteryRechargeable and field-replaceable
Software supportSupported from ValProbe RT software version 1.6

Base Station

The ValProbe RT Base Station connects the wireless loggers to the system software for qualification, calibration and verification studies. Once a study has started, it can operate independently of the console.

SpecificationValProbe RT Base Station
Dimensions190 × 130 × 55 mm
Internal memory32 GB
Power supply100–240 V
Antenna arrangementDual antennas
External antenna optionSupports an autoclave antenna
Independent study operationYes
Battery backupIncluded
Status indicatorsStudy and battery indicators
Logger activationWake-up function

Why Choose Kaye ValProbe RT?

Kaye ValProbe RT brings live process measurements, flexible sensor configurations and dedicated validation software together in one system.

The wireless design simplifies sensor positioning, while real-time data helps users follow study progress and identify unexpected conditions during a run. Logger options cover applications from low-temperature storage and freeze dryer shelves to steam sterilisation and dry heat processes.

the work surrounding each validation study. Withnell Sensors can help you identify suitable logger types, sensor configurations and supporting equipment for your application, whether you are planning a new system or reviewing an existing setup.

DOWNLOAD

Download the Kaye ValProbe RT Brochure

Explore the logger range, sensor configurations, technical specifications, base station and validation software in the Kaye ValProbe RT brochure.

team-headshot team-headshot team-headshot
30+