Withnell Sensors - Spell Out Logo
DataTrace Temperature Data Loggers – image 1
DataTrace Temperature Data Loggers – image 2
DataTrace Temperature Data Loggers – image 3
DataTrace Temperature Data Loggers – image 4
DataTrace Temperature Data Loggers – image 5
DataTrace Temperature Data Loggers – image 6
DataTrace Temperature Data Loggers – image 1
DataTrace Temperature Data Loggers – image 2
DataTrace Temperature Data Loggers – image 3
DataTrace Temperature Data Loggers – image 4
DataTrace Temperature Data Loggers – image 5
DataTrace Temperature Data Loggers – image 6

DataTrace Temperature Data Loggers

[6 Models]

DataTrace temperature data loggers provide accurate temperature monitoring across validation, sterilisation, thermal processing, storage and controlled manufacturing applications.

The range includes compact MPIII loggers for self-contained data collection, wireless MPRF loggers for real-time process visibility and specialist probe configurations for vials, sealed containers, pipework and difficult-to-access measurement points. Depending on the selected model and thermal protection, temperatures from -80°C to +400°C can be monitored.

  • Specialist configurations for diverse products, equipment and processes
  • High-accuracy temperature monitoring across an extensive operating range
  • Choice of self-contained logging or real-time wireless data

High-Accuracy Monitoring

Capture reliable temperature measurements during critical validation and thermal processes.

Standalone or Wireless Data

Choose self-contained MPIII logging or real-time wireless MPRF monitoring.

Specialist Probe Options

Monitor vials, containers, pipework, products and difficult-to-access locations.

Built for Validation

Designed for demanding pharmaceutical, food-processing and industrial applications.

DataTrace temperature data loggers support applications ranging from low-temperature storage to high-temperature processing. The choice of compact, wireless and specialist probe configurations allows measurements to be taken close to or directly inside products, containers and processing equipment.

  • Autoclave and steriliser validation
  • Pasteurisation and thermal processing
  • Chilling, freezing and controlled storage
  • EtO sterilisation and depyrogenation
  • Lyophilisation and freeze drying
  • Vial and bottle temperature monitoring
  • Canning and pouch processing
  • Steam-in-place and clean-in-place systems
  • Product and ambient temperature comparison
  • Pharmaceutical and food manufacturing

Withnell Sensors can help you select the appropriate logger, probe format and thermal protection for your process and operating temperature.

Extensive Temperature Range

Monitor temperatures from -80°C to +400°C, depending on the selected logger, probe and thermal protection configuration.

Standalone or Real-Time Data

Choose compact MPIII loggers for self-contained data collection or wireless MPRF models for real-time process visibility.

High Measurement Accuracy

Selected models provide accuracy down to ±0.1°C, supporting reliable validation, qualification and process-monitoring studies.

Application-Specific Configurations

Choose Micro Flex, Thermowell, Dual Probe or Needle Tip configurations for vials, sealed containers, pipework and challenging measurement locations.

NIST-Traceable Calibration

Factory calibration provides traceable measurement data to support quality control, validation and regulatory requirements.

Durable Construction

Stainless-steel construction and suitable thermal protection enable reliable monitoring in demanding low- and high-temperature processes.

Secure Data Management

DT Pro software supports study configuration, data analysis and secure reporting in accordance with FDA 21 CFR Part 11 requirements.

Intrinsically Safe Options

ATEX certification supports suitable use within applications where intrinsic safety is required.

Core Temperature Data Loggers

SpecificationMPIII Temperature Data LoggerMPRF Temperature Data Logger
Data collectionInternal loggingReal-time wireless or internal logging
Operating temperatureDown to -20°C
Up to +400°C with MPIII HiTemp EXT
-80°C to +140°C
+100°C to +360°C with HiTemp EXT thermal pack
-40°C to +400°C with thermal protection
Temperature accuracy±0.1°C for MPIII Temp
±0.5°C for MPIII HiTemp
±0.3°C from -80°C to -40°C
±0.1°C from -40°C to +140°C
Wireless rangeNot applicableUp to 30 m line of sight
Radio frequencyNot applicable2.4 GHz ISM band
Memory16,000 temperature observations8,192 observations
16,384 in compressed mode
Sampling interval1 second to 1 hourWith radio: 5 seconds to 1 hour
Without radio: 1 second to 1 hour
Resolution0.001°CNot specified
Dimensions18 × 20 mm, excluding probe23.2 × 94 mm
Weight15 g66 g
Construction316 stainless steel with sapphire IR windows316 stainless steel with ULTEM or PCTFE
CalibrationNIST-traceable factory calibrationNIST-traceable factory calibration or field calibration
BatteryField-replaceable lithium batteryField-replaceable AA lithium battery
Battery lifeNot specified6 months to 1 year, depending on use
Clock accuracy26 seconds per 24 hours10 seconds per 24 hours at +25°C
CertificationATEX for intrinsic safetyATEX for intrinsic safety; FCC Part 15 compliant
Compatible softwareDT ProDT Pro

Specialist Temperature Logger Configurations

SpecificationMicro FlexThermowellDual Probe MPIIINeedle Tip MPIII
Primary applicationLyophilisation, freeze drying and vial monitoringCanning, sealed containers, SIP and CIPTwo-point product and ambient monitoringAutoclave cycles, vials and restricted spaces
Data collectionReal-time capableInternal loggingInternal loggingInternal logging
Operating temperature-80°C to +140°C-20°C to +140°CDown to -20°C
Up to +400°C with HiTemp EXT
Down to -20°C
Up to +400°C with HiTemp EXT
Temperature accuracy±0.35°C from -80°C to -40°C
±0.2°C from -40°C to +140°C
±0.1°C±0.1°C for MPIII Temp
±0.5°C for MPIII HiTemp
±0.1°C for MPIII Temp
±0.5°C for MPIII HiTemp
Number of measurement pointsUp to twoOneTwoOne
Memory8,192 observations
16,384 in compressed mode
16,000 observations16,000 observations16,000 observations
Sampling intervalWith radio: 5 seconds to 1 hour
Without radio: 1 second to 1 hour
1 second to 18 hours1 second to 1 hour1 second to 1 hour
ResolutionNot specifiedNot specified0.001°C0.001°C
Logger dimensions23.2 × 94 mmNot specified18 × 20 mm18 × 20 mm
Weight170 g15 g15 g15 g
Construction316 stainless steel with ULTEM or PCTFE316 stainless steel with sapphire IR windows316 stainless steel with sapphire IR windows316 stainless steel with sapphire IR windows
CalibrationNIST-traceable factory or field calibrationNIST-traceable factory or field calibrationNIST-traceable factory calibrationNIST-traceable factory calibration
BatteryField-replaceable AA lithiumField-replaceable lithiumField-replaceable lithiumField-replaceable lithium
CertificationATEX; FCC Part 15 compliantATEXATEXATEX

Why Choose DataTrace Temperature Data Loggers?

DataTrace temperature data loggers combine accurate measurement with a wide choice of logger and probe configurations. From compact standalone devices to wireless real-time systems, the range can support monitoring across products, containers, equipment and complete thermal processes.

Specialist Micro Flex, Thermowell, Dual Probe and Needle Tip options make it possible to collect meaningful measurements from vials, sealed systems, pipework and restricted locations. NIST-traceable calibration and FDA 21 CFR Part 11-compliant software support dependable results and auditable records in regulated environments.

As an authorised DataTrace supplier, Withnell Sensors can help you select the correct logger, probe configuration and thermal protection, then provide system configuration, training and ongoing technical support.

DOWNLOAD

Download the DataTrace Temperature Data Logger Brochure

Download detailed specifications, model comparisons and application guidance for the complete DataTrace temperature logger range.

team-headshot team-headshot team-headshot
30+